CGDHS - IN-CERAM SPACER VARNISH, A87-252
- MSDS: CGDHS
- Manufacturer: VIDENT
- Product Name: IN-CERAM SPACER VARNISH, A87-252
- National Stock Number: 6520-00N082617
Product Identification
Product ID:IN-CERAM SPACER VARNISH, A87-252
MSDS Date:07/06/1992
FSC:6520
NIIN:00N082617
MSDS Number: CGDHS
Responsible Party
BALDWIN PARK, CA 91706
US
Emergency Phone: 818-960-7531
Info Phone: 818-960-7531
Cage: 67251
Contractor
Telephone: 818-962-4220
Cage: 67251
Ingredients
ACETONE (SARA 313) (CERCLA)
CAS: 67-64-1
RTECS: AL3150000
OSHA PEL 1000 PPM
ACGIH TLV: 750 PPM/1000 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
CELLULOSE ACETATE,
CAS: 9004-35-7
OSHA PEL N/K
ACGIH TLV: N/K
ISOPROPYL ALCOHOL (SARA 313)
CAS: 67-63-0
RTECS: NT8050000
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM/500 STEL
ACETIC ACID, ETHYL ESTER; (ETHYL ACETATE) (CERCLA)
CAS: 141-78-6
RTECS: AH5425000
OSHA PEL 400 PPM
ACGIH TLV: 400 PPM
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
LACTIC ACID, BUTYL ESTER; (N-BUTYL LACTATE)
CAS: 138-22-7
RTECS: OD4025000
OSHA PEL 5 PPM
ACGIH TLV: 5 PPM
METHOXY-PROPYL-ACETATE
OSHA PEL N/K
ACGIH TLV: N/K
TOLUENE (SARA 313) (CERCLA)
CAS: 108-88-3
RTECS: XS5250000
OSHA PEL 200 PPM; Z-2
ACGIH TLV: S, 50 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRITATES EYES & MUCOUS
MEMBRANES. INGESTION: INTOXICATION AND REDUCES THE ABILITY TO
REACT. TOLUENE APPEARS ON THE NAVY LISTING OF OCCUP CHEM REPROD
HAZARDS. SEEK CONSULTATION FROM APPROP HLTH PROFESSIONALS
CONCERNING LATEST HAZARDLIST INFO & SAFE HNDLG & EXPOS INFO .
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INGEST: CALL MD IMMEDIATELY . INHAL: REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE OXYGEN/ARTIFICIAL RESPIRATION SKIN & EYE:
FLUSH WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. SE EK
MEDICAL ATTENTION IF IRRITATION PERSISTS.
Fire Fighting
Flash Point:<42F,<6C
Lower Limits:2.5%
Upper Limits:17%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL OR FOAM.
Fire Fighting Procedures:NONE. WEAR NIOSH APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE.
Accidental Release
Spill Release Procedures:DO NOT WIPE. LET ABSORB ON PAPER TOWEL. ABSORB
IN VERMICULITE, DRY SAND, EARTH, OR SIMILAR MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:KEEP AWAY FROM HEAT AND OTHER IGNITION
SOURCES.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NIOSH APPROVED NUISANCE DUST MASK RECOMMENDED.
Ventilation:MECHANICAL EXHAUST VENTILATION RECOMMENDED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:AVOID LICKING CERAMIC APPLICATION BRUSH.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
Chemical Properties
Boiling Pt:B.P. Text:71.0F,21.7C
Vapor Pres:18 @ 77F
Vapor Density:0.9
Spec Gravity:0.899
Evaporation Rate & Reference:33 MG/MIN
Solubility in Water:IMMISCIBLE
Appearance and Odor:RED, ACRID ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL,
STATE, AND LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.